In the context of rapid development of manufacturing industry today,J23-25
plain press has become an ideal choice for many enterprises to improve production efficiency and reduce costs due to its excellent performance and wide application fields.Recently,with the continuous growth of market demand for high-precision and high-efficiency stamping equipment,J23-25 plain press has once again become the focus of industry attention.
The normal standards for the electrical system of J23-25 plain press mainly include the following aspects:
1.Integrity of electrical components
Ensure that all electrical components such as relays,contactors,switches,buttons,etc.are intact and free from burning,deformation,or looseness.Check whether the electrical wiring of J23-25 plain press is firm and reliable,without exposure,short circuit or open circuit.
2.The control circuit functions normally
After pressing the start button,the J23-25 plain press should be able to start smoothly;After pressing the stop button,the device should be able to quickly and smoothly stop running.The emergency stop button should be able to quickly cut off the power supply,ensuring the safety of personnel and equipment in emergency situations.Each indicator light should be able to correctly display the working status of the equipment,such as operation,faults,etc.
3.Stable power supply voltage
Use a voltmeter to measure the power supply voltage,ensuring that it fluctuates within the rated range and avoiding damage to the equipment caused by high or low voltage.Observe the fluctuation of power supply voltage to ensure its stability during equipment operation.
4.Effective protective device
Ensure that overload protection devices(such as thermal relays)can work properly and automatically cut off power when the equipment is overloaded,preventing equipment damage.Check if the short-circuit protection device(such as fuse)is intact to ensure that the power can be quickly cut off in the event of a short-circuit fault.
5.Good grounding
Use a grounding resistance tester to measure the grounding resistance of the equipment and ensure that it meets safety standards.Check whether the grounding wire of J23-25 plain press is firmly connected,without rust or breakage
6.Electrical system cleaning and heat dissipation
Regularly clean the electrical system,remove dust and oil stains,and maintain the heat dissipation performance of electrical components.Check the heat dissipation of electrical components to ensure there is no overheating phenomenon.
In summary,the normal standards for the electrical system of J23-25 plain press include the integrity of electrical components,normal control circuit function,stable power supply voltage,effective protection devices,good grounding,and cleanliness and heat dissipation of the electrical system.The implementation of these standards helps ensure the safe,stable,and efficient operation of the punch press.